Investigating indoor concentrations of PM10 in an underground loading dock in Malaysia
Date
2017
Journal Title
Journal ISSN
Volume Title
Publisher
Springer
Abstract
Risky air contaminants including PM10 can accumulate inside underground confined loading docks because of the enclosed nature and limited contacts of loading docks with ambient air. Exposure to PM10 can increase morbidity and mortality rates. Hence, this study aimed to investigate and model PM10 concentrations in an underground loading dock located at Kuala Lumpur city center, Malaysia.
Description
Keywords
Particulate matters forecasting, PM10, Temporal variation, Indoor air quality, Diesel-powered vehicles, Underground microenvironment
Citation
Abualqumboz, M. S., Mohammed, N. I., Malakahmad, A., & Nazif, A. N. (2017). Investigating indoor concentrations of PM 10 in an underground loading dock in Malaysia. Air Quality, Atmosphere & Health, 10, 147-159.